Skip to main content
Loading…
Proof
This section is included in your selections.

In an F-P zone, the following limitations shall apply:

A. No residence shall be constructed;

B. A lot shall not be less than one acre in area;

C. Within the floodway and flood fringe, no encroachment will be allowed which causes any increase in the flood height or which would result in hazardous velocities (see floodway schematic). To demonstrate compliance with this requirement, the applicant shall submit an engineering certification stating the proposed development will not impact the pre-project base floodway and flood fringe elevations. The certification shall be signed and sealed by a professional engineer and be supported by the appropriate technical data and studies, which are typically based upon the standard step-backwater computer model utilized to develop the 100-year floodway and flood fringe shown on the appropriate Federal Insurance Rate Map (FIRM) and tabulated in the adopted Flood Insurance Study. (Ord. 4921 §4D, 2010; Ord. 4684 §3, 1998; Ord. 4128 (part), 1981; Ord. 3380 (part), 1968).