Lot grading shall conform to the following standards unless physical conditions demonstrate the propriety of other standards:

A. Cut slopes shall not exceed one and one-half (1½) feet horizontally to one foot vertically.

B. Fill slopes shall not exceed two feet horizontally to one foot vertically.

C. The character of soil for fill and the characteristics of lots made usable by fill shall be suitable for the purpose intended.

D. The minimum elevation at which a structure may be erected, taking into consideration the topography of the lot, the surrounding area, drainage patterns, and other pertinent data shall be established by the city building official.

E. The city engineer shall determine whether a storm drainage system is necessary to control, manage, and dispose of water lying on or running over a subdivision. In addition, the subdivider shall be required to meet other standards and conditions imposed by state laws and city ordinances.