Skip to main content
Loading…
Proof
This section is included in your selections.

A. Category 1. The following installations are permitted subject to the general standards in Section 3.18.755. For wood poles authorized to remain, the general standards allow for top-mounted canister-style antennas or side-mounted panel-style antennas, wire and cabling are authorized within conduit, and an integrated equipment cabinet in the base of the pole is not required.

1. Type 1. Attachment to an existing wood pole for overhead power transmission.

2. Type 2a. Attachment to existing wooden pole for a streetlight where a replacement pole is determined to be infeasible by the pole owner.

B. Category 2. The following installations are permitted subject to the general standards in Section 3.18.755. If the existing poles are not already designed by the manufacturer for additional antenna and equipment attachments, the existing poles must be replaced with poles designed to accommodate SWFs, which allow for internal cabling and wiring, and include an integrated equipment cabinet in the base of the pole which meets the standards of Section 3.18.755. Only top-mounted canister-style antennas are permitted; side-mounted panel antennas are not permitted. As used in this article, “replacement pole” means a pole meeting the requirements described above.

1. Type 2b. Attachment to replacement pole for existing wooden streetlight served by overhead power, or replacement pole for other existing wooden pole without overhead power which serves only as a support for other overhead wires.

2. Type 3. Attachment to existing streetlight pole or replacement pole served by underground power.

3. Type 4. Attachment to pole supporting traffic control devices or combined pole that also supports other uses such as streetlights. A wooden pole supporting traffic control devices shall be replaced with a replacement pole.

4. Type 5. Attachment to existing decorative pole or replacement pole.

5. Type 6. Attachment to existing freestanding SWF pole or replacement pole.

C. Category 3. The following installations are prohibited, except that a Type 7 installation may be authorized by the city if the applicant shows by clear and convincing evidence that co-location on a Category 2 pole type is not possible. If authorized, the pole must be designed for SWF installation with internal wiring and cabling and include an integrated equipment cabinet in the base of the pole which meets the standards of Section 3.18.755. Only top-mounted canister-style antennas are permitted, and side-mounted panel antennas are not permitted.

1. Type 7. Attachment to new freestanding small cell pole.

2. Type 8. Strand-mounted attachment. (Ord. 5067 §1 (Exh. A (part)), 2019).